Leading Manufacturers, Exporters, Wholesaler, Retailer and Trader of Dual Channel Dust Sampler, PM10 High Volume Air Sampler and PM2.5 High Volume Air Sampler from Mumbai.
Business Type | Manufacturer, Exporter, Supplier, Retailer, Wholesaler, Trader, Distributor, Importer |
Feature | Durable, Fine Finished |
Model | IPM-FDS 2510 |
Dust Instruments Measurement | Pm2.5 & Pm10 |
PM 2.5 Size Separator | Separate set of inlet assembly with EPA PM 2.5 WINS Impactor |
Bar Press Sensor | Range 600 to 800 mm Hg. Resolution, 1 mm Hg |
Leak Test | Internal & External Leak check feature for accurate sampling. |
Details | View |
Preferred Buyer From
Location | Worldwide |
When it comes to innovation in Ambient Air Sampling technology, Instrumex has delivered yet again! The most common hassle faced by Consultants in order to comply with the CPCB norms for Ambient Air Sampling - was using two separate instruments for measurement of PM2.5 & PM10 Dust. Instrumex has found the solution to this problem - The Dual Channel Sampler for measurement of PM2.5 & PM10 dust concentrations in ambient air – Simultaneously!
The flow control module uses the proven technology used in Instrumex's IPM-FDS 2.5/10µ Fine dust Sampler that has enjoyed over 400 installations across India and abroad. The two channels in IPM-FDS-2510 are individually controlled by separate flow control element but integrated into a single controller module. Thereby giving precise microprocessor based flow control for two channels. Both the channels individually comply with Federal Reference Method of USEPA as described in 40 CFR Part-50 Appendix L for determination of Particulate Matter. It also confirms with the CPCB guidelines for Measurement of Ambient Air Pollutants.
Features
Business Type | Manufacturer, Exporter, Supplier, Retailer, Wholesaler, Trader, Distributor, Importer |
Preferred Buyer From
Location | Worldwide |
Instrumex Respirable Dust Sampler is a versatile dust sampler that is based on a design standardized by CPCB for collection of PM10 & Totoal Suspended Particulates (TSPM) in ambient air and also simultaneously samples the particulates having aerodynamic diameter less than 10 Micron.
Features
Instrument Overview
Instrumex Respirable Dust Sampler employs heavy duty Brushless and Noiseless blower that draws air through a size-selective inlet and through a 20.3 X 25.4 cm (8 X 10)" filter at a flow rate, which is typically between 0.9 — 1.4 m3/min maintained by an Orifice. A cyclonic flow technique is used to separate the particles with aerodynamic diameter less than the cut-point of the inlet (PM10). These are collected by the filter. The particles greater than 10 micron are separated at the bottom of the cyclone into a dust collecting bottle. The mass of PM10 particles is determined by the difference in filter weights prior to and after sampling. The concentration of PM10 in the designated size range is calculated by dividing the weight gain of the filter by the volume of air sampled.
Gaseous Sampling
Normal Gaseous Sampling Kit:
Aluminum enclosure housing an Ice tray attached at the back of the instrument with following provisions:
Thermoelectric Gaseous Sampling Kit:
In tropical weather where temperatures can soar above 35°C, the reagents in the impingers tend to evaporate quickly. This results in erroneous reporting of the Gaseous pollutants. Instrumex Thermoelectric Gaseous Sampling Kit is a separate enclosure with a Peltier cooling system that automatically maintains temperature between 10 - 15°C. Thereby completely eliminating the hassle of replacing the ice/cold water after every few hours
Optional Extras
Business Type | Manufacturer, Exporter, Supplier, Retailer, Wholesaler, Trader, Distributor, Importer |
Brand Name | IPM-FDS 2.5/10 Micron |
PM 2.5 Size Separator | U.S. EPA designed PM25 Wins Impactor |
PM 10 Size Separator | U.S. EPA Omni-directional ambient particle inlet with 10µ separation assembly sample transport tube |
Air sampling Filtration Media | Suitable for 47mm filter in special Delrin Filter cassette carrier housed in filter holder assembly |
Flow Control | Flow control by critical orifice at 1m3/hr unaffected by voltage fluctuation |
Volume Totaliser | Totalized volume readings available on Dry Gas Meter |
Leak Test | Internal & External Leak check feature for accurate sampling |
Vacuum Pump | A diaphragm type pump with AC motor for reliable & low noise operation |
Power Requirement | 230 V AC 10% ± 50 Hz |
Dimension & Weight | Sampler Size (16X13X24)". Total height with Inlet and Stand (5.5)'. Approx 25 Kgs |
Preferred Buyer From
Location | Worldwide |
Instrumex Ambient Fine Dust Sampler is designed as per USEPA guidelines for sampling of PM2.5 and PM1 0 particles in Ambient Air. The USEPA based WINS impactor separates the particles smaller than 2.5p by the principle of impaction at a regulated flow of 1 m3/hr. A critical orifice controls the flow throughout the sampling period. PM1 0 particle sampling is achieved by replacing the WINS impactor with a downtube.
Key Features
Clock / Timer System
Programmable Real Time control system with automatic start & stop Digital display of date, time & time of sampling. Accuracy ± 2 min / month.
Optional Gaseous Sampling Attachment
Thermoelectric Gaseous Sampling Kit
In-built Gaseous Sampling Kit
Hi! Simply click below and type your query.
Our experts will reply you very soon.