Ambient Air Quality Monitoring Station in compliance with the USEPA & CPCB (Delhi)
Accessories
Business Type | Manufacturer, Exporter, Supplier, Retailer, Trader, Distributor, Importer |
Principle | Backward Scattering |
Ranges | 0-200 mg/m3 |
Accuracy | +/- 2 FS |
Repeatability | 1% FS |
Response Time | 1S |
Power | <3W |
Supply | 24V Dc +/-10% |
Preferred Buyer From
Location | Worldwide |
PE-SPMMS-C91 (LBS) is an on-line dust monitoring device using the mainstream technology of laser back scattered light principle with imported core components. PE-SPMMS-C91(LBS) is mainly used for continuous monitoring of various sources emissions of particulate matter concentrations. It can be either Equipped either with CEMS .
It is available for monitoring and control of soot emission , flue gas DeSOx and removal of dust for power generation boilers, industrial furnaces , industrial boilers in the thermal power, iron and steel metallurgy , petrochemical , chemical , cement production, ceramics , waste incineration etc.
Key Features
Business Type | Manufacturer, Exporter, Supplier, Retailer, Trader, Distributor, Importer |
Power Supply | 220V AC, 5000W |
Heating Temperature | 1200C -1800C |
Operating Temperature | 200C – 500C |
Operating Humidity | 0-95% RH (Non- condensing) |
External Output | 10 x 4 -20mA, 1 x RS232, 1 x RS485 |
Compressed Air Requirement | (0.4-0.8)mPa/115psi 0.25m3/min |
Dimension | 800mm x 600mm x 1800mm (Configuration dependent ) |
Additional Information | ![]() |
Preferred Buyer From
Location | Worldwide |
Gas Sample in flue gases passes through the probe, primary filtration, sampling ball valve and secondary filtration in the chassis, then reaches to measuring cell. After analysis the density and humidity of all components the sample gas will be drained through sampling pump.
By controlling sampling ball valve and back-blowing solenoid valve, the system can regularly back –blow to the probe. It can also realize the regular calibration of the analyzer by controlling and calibration solenoid valve.
Key Features
Business Type | Manufacturer, Exporter, Supplier, Retailer, Trader, Distributor, Importer |
Application | Industrial Use |
Feature | Durable, High Speed |
Voltage | 220V |
Frequency | 50HZ |
Warranty | 1year |
Preferred Buyer From
Location | Worldwide |
EQMS (Effluent Quality Monitoring System) technology is based on unique method FTLS UV spectroscopy which associate proprietary high resolution spectrograph with Fourier Transform & Least Square mathematical treatment. So, you can believe in our knowledgeable and responsive support team to address your unique needs for the water or air applications throughout your entire process.
Our goal for the future is to continue to provide customers with reliable instruments, proven methods, easy procedures, and outstanding technical support. We will strive to be best choice brand offering trust and assurance to our customers.